Fault | Cause | Solution |
Excessive shaft power | 1.Impeller rubbing | 1.Adjust impeller position |
2.Excessive flow rate | 3.Increase discharge line resistance | |
Insufficient head | 1.Worn seal ring | 1.Replace seal ring |
2.Strainer or passage clogged | 2.Remove blockage | |
3.Severely worn impeller | 3.Replace impeller | |
Insufficient flow rate | 1.System head too high | 1.Reduce system head |
2. Strainer or passage clogged | 2.Remove blockage | |
3.Worn flow-passing components | 3.Replace worn parts | |
4.Worn seal ring | 4.Replace seal ring | |
Rolling bearing overheating | 1.Excessive or insufficient grease | 1. Adjust grease quantity |
2.Grease deteriorated or contaminated | 2.Replace grease | |
3.Bearing worn | 3. Replace bearing | |
Vibration and noise | 1.Non-uniform impeller wear | 1.Replace impeller |
2. Roller bearing worn or damaged | 2.Replace bearing | |
3.Shaft bent | 3.Straighten or replace shaft | |
4. Air ingress into pump suction | 4Eliminate air ingress |