Sichuan Sino-British Industrial Pumps
The D-type multistage centrifugal pump
The D-type multistage centrifugal pump is in operation.
Fault Phenomenon | Possible Cause | Solution |
Pump does not prime; pressure gauge and vacuum gauge needles fluctuate violently | 1.Insufficient priming water 2.Air leakage at pipe or instrument connections 3. Suction lift too high | 1. Check if foot valve leaks; refill with sufficient priming water 2.Tighten leaking points 3.Reduce suction height |
Pump does not prime; vacuum gauge indicates high vacuum | 1. Foot valve not opened or clogged 2.Excessive resistance in suction line 3.Strainer clogged | 1.Inspect foot valve 2.Replace suction line 3.Clean strainer |
Pressure gauge shows pressure but no water is discharged | 1.Excessive resistance in discharge line 2.Incorrect rotation direction 3.Discharge valve not opened 4.Impeller clogged | 1.Inspect or shorten discharge pipe 2.Check motor; interchange two phases 3.Open discharge valve 4.Remove debris from impeller |
Design flow rate not achieved | 1.Air ingress 2. Insufficient submergence due to lowered water level 3. Foreign matter clogging impeller 4.Severe wear of rotating parts | 1.Locate and eliminate air leakage 2.Extend suction pipe; increase submergence depth 3.Disassemble and remove foreign matter 4.Replace seal ring |
Excessive power consumption | 1.Packing gland too tight and overheating 2. Flow rate too high 3.Rubbing between rotating element and casing 4.Pump bearing worn 5.Pump shaft bent | 1.Loosen appropriately 2.Partially close gate valve 3.Trim or repair 4.Replace bearing 5.Replace or straighten shaft |
Excessive pump vibration | 1.Partial clogging of impeller 2. Impeller damaged 3.Flow rate too low 4.Pump shaft and motor shaft misaligned 5.Bearing damaged 6.Air ingress causing cavitation | 1.Disassemble and remove foreign matter 2.Replace impeller 3.Slightly open discharge valve 4.Align shafts by dial gauge 5.Replace bearing 6.Change suction position; improve suction line |